2-2 is Viking's fill error: the expected fill was not detected.
Model compatibility: Viking reuses codes across series and model years, so 2-2 may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
The fill was not detected as expected, either by pressure sensor or, on models without one, by temperature change.
The signal 2-2 (two flashes Pots/Pans, two flashes Normal Wash) shows up when the water the control expected to take in did not register. Viking’s checklist leans toward the water supply, so begin there.
At a glance
| Code | 2-2 |
|---|---|
| What it means | The fill was not detected as expected, either by pressure sensor or, on models without one, by temperature change. |
| What you can check | Make sure the valve feeding the dishwasher is open, the fill line has no kink, and the machine is level front to back and side to side. House water pressure may also have dropped. |
| When to call a technician | If 2-2 persists after the supply checks, a technician needs to test the sensor, the inlet valve coil and the control, which involves line voltage. |
Step list from the manuals
- Is the valve that feeds the dishwasher open?
- Is there a kink in the fill line?
- Is the machine level from front to back and from side to side? (VDB451 and VDB325/450)
- Has pressure in the house supply dropped?
For the VDB200, the same fault is labelled “fill time-out.” A technician is told to verify water pressure and to make sure the inlet hose and water valve are free of restriction.
What the control looks for
With a pressure sensor, the control expects the sensor output to reach a target pressure during the fill. When it does not, 2-2 is set, and after the simple checks the VDB451 and VDB325/450 manuals list a defective sensor or control; the VDB325/450 adds the inlet valve.
Without a pressure sensor (the FDB301 group), a temperature change is the sign that water is coming in. If none is seen, the control concludes nothing arrived, and the manual then names the thermistor or the control. In the VDB451 manual, the water temperature sensor on the 200 Series also serves as the water input sensor.
Where owner checks end
With a good supply, hose and level, the sensor, the inlet valve coil (about 1.1K ohms per the VDB451 manual) and the control are the next suspects. Testing them involves line voltage.
Reading the two models together
A machine without the pressure sensor uses a temperature change as the sign of water and lists the thermistor. The checks before the parts are the same for both: supply valve, fill line, levelling and house pressure.
Linked codes
Viking dishwasher repair in Miami, New York, Houston, Los Angeles and San Diego
Our number for these metro areas is (844) 363-0467. If 2-2 persists after the supply checks, tell us the model, the code and what you tried. Browse the dishwasher repair page too.
Source: Viking Preferred Service Manual SMK-0005; SMK-0006; SMK-0003; SMK-0002
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
- Viking Preferred Service Service Manual Built-In Dishwasher FDB451 VDB451, SMK-0005, Aug 2012 (Fail Codes, pp.12-13), hosted on uncleharrywizard.com
- Viking Preferred Service Service Manual Built-In Dishwasher FDB301 RDDB201 RDDB301 VDB301, SMK-0006, Apr 2012 (Fail Codes, pp.12-13), hosted on uncleharrywizard.com
- Viking Preferred Service Service Manual Built-In Dishwasher VDB325 VDB450 (from 5/26/2010) VDB325E VDB450E, SMK-0003, Apr 2011 (Error Codes, pp.19-21), hosted on uncleharrywizard.com
- Viking Preferred Service Service Manual Built-In Dishwasher VDB200, SMK-002, May 2010 (Fail Codes, p.13), hosted on uncleharrywizard.com
Model, symptom, ZIP — we’ll confirm a visit
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.