CL on the temperature display means the condenser coil needs cleaning, then UP and DOWN for 3 seconds.
Model compatibility: Viking reuses codes across series and model years, so CL may mean something different on another appliance or generation. Confirm this against your model’s documentation and record your full model number before acting.
What this code means
A blinking CL on the refrigerator display is the prompt to clean the condenser coil.
If the temperature display of a Viking 7 Series integrated refrigerator blinks CL, the unit is not signalling a failure. It is prompting a clean of the condenser coil, which collects dust, pet hair and construction debris that hinder heat release.
At a glance
| Code | CL |
|---|---|
| What it means | A blinking CL on the refrigerator display is the prompt to clean the condenser coil. |
| What you can check | CL is a cleaning reminder, not a failure. Vacuum dust off the front surface of the condenser coil, then hold the UP and DOWN arrows together for 3 seconds to clear it. |
| When to call a technician | If CL returns soon after cleaning, or you would rather not take the unit apart, a technician can check the coil and controls. First make sure the 3-second hold was complete. |
Recommended frequency
Clean it every 6 months, or sooner when construction or other dust-raising work has taken place.
Procedure from the manual
- Turn off the main power switch under the top access panel at the top of the unit.
- Pull out the bottom freezer drawer to its limit, release the clips at the back and lift the drawer out.
- Loosen the kick plate’s two screws and slide it out through the keyhole.
- Remove the access panel’s two screws and pull hard to unsnap the panel.
- Use a household vacuum with an extension on the coil’s front surface, removing all dust. Viking prefers this to a duster since a duster may damage the fins.
- Put the access panel and kick plate back.
- Restore the main power switch and replace the top access panel.
- Hold UP and DOWN arrows together for 3 seconds to remove CL.
If it returns soon
A dirty coil is the only cause the manual gives, and it offers nothing for a repeat. Check the 3-second hold was complete. If CL still comes back, the coil and controls can be checked by a technician.
Related
- BLUEZONE: bulb reminder on this display
- HIGH TEMPERATURE ALARM: for a cabinet that is actually too warm
Refrigerator repair for CL that will not clear
Our Viking calls cover the Miami, New York, Houston, Los Angeles and San Diego metro areas. Call (844) 363-0467 if you would rather not take the unit apart or CL stays on. See refrigerator repair.
Source: Viking 7 Series Integrated Refrigerator/Freezer Use & Care Manual
Important safety warning. Do not attempt repairs involving electrical components, gas, water lines, refrigerant or sealed systems. Unplug the appliance if it is safe to reach the outlet, and leave internal diagnostics to a qualified technician.
Sources & references
Model, symptom, ZIP — we’ll confirm a visit
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.